Call Us

+1(956)-269-9999

Refrigerated Dryer

Compressor air Dryer 353.15CFM 50KW/75HP refrigerated air Dryer 102-145psi Single Phas 220V

Model:LDN 355

Air Capacity : 353.15CFM

Electrical :1 Phase

Interface size : 1-1/2

Working Operating pressure : 102-145 PSI

Cooling : By Air

Ambient temperature : 0-95°F

Intake air temperature :<113°F

Power supply : 220V/60Hz

Refrigerant type : R410a

Installed power : 2000W

Dimension : 50*21.65*43.11 Inch

Weight :353.15lb

Warranty : 1 Year

Product Details
Technical Parmeters
Catalogue Download

Compressor air Dryer 353.15CFM 50KW/75HP refrigerated air Dryer  102-145psi 220V  Single Phas


Model:LDN 355

Air Capacity : 353.15CFM

Electrical :1 Phase

Interface size : 1-1/2

Working Operating pressure : 102-145 PSI

Cooling : By Air

Ambient temperature : 0-95°F

Intake air temperature :<113°F

Power supply : 220V/60Hz

Refrigerant type : R410a

Installed power : 2000W

Dimension : 50*21.65*43.11 Inch

Weight :353.15lb

Warranty : 1 Year


Product Advantages :

1: Space saving: Help users save space when installation space is insufficient.

2: Cost saving: The integrated design of dryer and filter saves time and manual installation, and reduces maintenance costs.

3: In response to the international Montreal Protocol, this series of models all use R134a and R410a environmentally friendly refrigerants, which have zero damage to the atmosphere and meet the needs of the international market.

4: The aluminum alloy three-in-one heat exchanger design minimizes the process loss of cooling capacity and improves the recycling of cooling capacity. Under the same processing capacity, the total input power of this model is reduced by 15-30%.

5: The integrated heat exchanger has guide fins added to make the compressed air evenly exchange heat inside, and the built-in air-water separation device is equipped with a stainless steel filter to make the water separation more thorough.

6: Multi-channel temperature and pressure monitoring, real-time display of dew point temperature, automatic recording of cumulative operating time, self-diagnosis function, display of corresponding alarm codes, and automatic protection of equipment.

7: Standard constant pressure expansion valve and intelligent temperature control. Laboratory tests show that the machine can still operate stably when the air intake temperature reaches 65℃ and the ambient temperature reaches 42℃. It also has dual antifreeze protection of temperature and pressure. When the machine runs at low load for a long time, it will automatically stop the output of the compressor and use the refrigeration capacity stored in the aluminum plate to provide heat exchange. This saves energy and extends the service life of the equipment.

Compressor air Dryer 353.15CFM 50KW/75HP refrigerated air Dryer 102-145psi Single Phas 220V

Compressor air Dryer 353.15CFM 50KW/75HP refrigerated air Dryer 102-145psi Single Phas 220V

Compressor air Dryer 353.15CFM 50KW/75HP refrigerated air Dryer 102-145psi Single Phas 220V


AIR COMPRESSOR MAINTENANCE

01

The air compressor shouldbe placed in a place withclean air and good ventilation.

The air compressor shouldbe placed in a place withclean air and good ventilation.

02

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

03

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

04

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

ENERGY SAVING THCHNOLOGY

Power saving of 17000o kWh per month

The starting power of the original system is 555kw,and the starting power of the new system is 320kw.

Power saving of 17000o kWh per month

Power saving of 54000 kWh per month

The starting power of the original system is 240kW,and the starting power of the new system is 132kw.

Power saving of 54000 kWh per month

Power saving of 86000 kWh per month

The starting power of the original system is 446kW,and the starting power of the new system is 325kW.

Power saving of 86000 kWh per month

Power saving of 260000 kWh per month

The starting power of the original system is 690kw,and the starting power of the new system is 420kw.

Power saving of 260000 kWh per month

Power saving of 167000 kWh per month

The starting power of the original system is 732kW,and the starting power of the new system is 50okw.

Power saving of 167000 kWh per month

Power saving of 79000 kWh per month

The starting power of the original system is 430kw,and the starting power of the new system is 320kw.

Power saving of 79000 kWh per month

Copyright © KAPA AIR COMPRESSOR LIMITED. All Rights Reserved | Sitemap