Call Us

+1(956)26-99999

KE Series  Laser-specific  Integrated  Gas Station

KE2 Series Laser-specific Integrated Gas Station

Laser-specific Integrated Gas Station

7-Level water removal device

8-Level oil removal device

7-Level dust removal device

Product Details
Technical Parmeters
Catalogue Download

Comparison between New Laser-specific Integrated Gas Station vs   Traditional Laser-specific Air Compressor

Purchase only brings happiness, but replacement brings a sense of accomplishment

画板 2-100.jpg

Fully Enclosed Oil-Cooled Motor

1. Cooling method - the oil-cooled motors are suitable for ambient temperatures ranging from -40 ℃ to +60 ℃ and are not affected by environmental dust and chemicals.

2. Cooling system - no attached cooling fan, no additional load increase, better dynamic balance and stability of the motor.

3. Protection level - IP65, fully enclosed structure, completely preventing foreign objects and dust from entering, and preventing water sprayed from each direction from entering the motor and causing damage.

4. Motor efficiency -> IE5 (motor body does not generate other heat losses, heat dissipation consumes power)

5. Magnetic steel grade - 48SHT/48UH

6. Magnetic steel temperature resistance -> 150 ℃

7. Variable frequency range - the variable frequency range is wider by 10% -100%, and the low frequency is not limited by the cooling capacity.

8. Fully enclosed structure, long service life, no external environmental interference factors.

Patented oil-gas tank

1. Adopt an enlarged horizontal oil-gas tank - the design ensures sufficient internal capacity space, and the main unit directly discharges the gas into the oil-gas tank, reducing pressure loss and pipeline faults,

2. There is an access port - can be regularly cleaned and maintained, and ensure the precision of internal manufacturing processes,

3. A shock absorber is installed - can prevent vibration transmission, reduce noise, and avoid pipeline loosening

4. Horizontal oil-gas tank design - although the manufacturing process is complex and the cost increases by 300%, the oil removal effect is improved by 50%

Desiccant air dryer

1. Structure and efficiency - multi-chamber modular design, compact structure and small volume, more than 50% smaller than traditional double-tower adsorption dryers under the same treatment flow rate;

2. Balanced airflow distribution - low pressure loss (below 0.03MPa), reducing gas loss.

High adsorption efficiency, customizable dew point of -40℃ or even lower, suitable for such industries as electronics and pharmaceuticals that require high air dryness.

3. Operating cost - low energy consumption, non-heat regeneration or waste heat regeneration technology, saving 30%-60% energy compared with traditional refrigerated dryers. The adsorbent has a long service lift (2-3 years), and is easy to replace, and the maintenance cost is reduced.

4. Maintenance and expansion - modular design supports flexible addition and reduction of adsorption towers to adapt to different treatment scales. The controller supports remote control and communication functions, simplifying operation and management;

Main unit1. Through independent R&D and design, achieve accurate fluid gap control; precise rotor profile design makes the product unique and distinct from the standard options of other manufacturers; the main unit is guaranteed for five years

2. Six-bearing structure, long rotor, large diameter, more stable, more reliable, low noise, long service life, high energy efficiency, large air capacity

画板 3-100.jpg




ModelAir displacement (cfm)Pressure (psi)Power (HP)Overall dimensions LWH (inches)Volume (gallon)Outlet sizeWeight (pound)Noise level DB (A)
KE2/15 - 1640.612321576.77×20.08×50.39118.8RP3/4109768±2
KE2/20 - 1658.982322076.77×20.08×50.39118.8RP3/4112368±2
KE2/30 - 1687.232323076.77×20.08×50.39118.8RP3/4127870±2
KE2/40 - 16145.852324086.61×24.02×50.39132RP1132272±2
KE2/50 - 16173.042325086.61×24.02×50.39132RP1132272±2
KE2/75 - 16212.2423275104.33×27.95×68.90264RP1 - 1/2176276±2
KE2/100 - 16278.63232100104.33×27.95×68.90264RP1 - 1/2187276±2


AIR COMPRESSOR MAINTENANCE

01

The air compressor shouldbe placed in a place withclean air and good ventilation.

The air compressor shouldbe placed in a place withclean air and good ventilation.

02

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

03

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

04

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

ENERGY SAVING THCHNOLOGY

Power saving of 17000o kWh per month

The starting power of the original system is 555kw,and the starting power of the new system is 320kw.

Power saving of 17000o kWh per month

Power saving of 54000 kWh per month

The starting power of the original system is 240kW,and the starting power of the new system is 132kw.

Power saving of 54000 kWh per month

Power saving of 86000 kWh per month

The starting power of the original system is 446kW,and the starting power of the new system is 325kW.

Power saving of 86000 kWh per month

Power saving of 260000 kWh per month

The starting power of the original system is 690kw,and the starting power of the new system is 420kw.

Power saving of 260000 kWh per month

Power saving of 167000 kWh per month

The starting power of the original system is 732kW,and the starting power of the new system is 50okw.

Power saving of 167000 kWh per month

Power saving of 79000 kWh per month

The starting power of the original system is 430kw,and the starting power of the new system is 320kw.

Power saving of 79000 kWh per month

Copyright © KAPA AIR COMPRESSOR LIMITED. All Rights Reserved | Sitemap