What Should You Check Before Starting and During Operation?

Nov. 24, 2026

A quick inspection before startup—and regular checks while the compressor is running—can help catch leaks, abnormal readings, and drainage issues early. Use this checklist as a guide, and follow the operating manual for your specific model. Recommended oil levels, temperature ranges, and maintenance procedures can vary by compressor.

Pre-Start Checklist

1. Confirm the power supply

Make sure the compressor is connected to the correct power supply and that the power indicator is on. If the indicator is off or an alarm appears, check the manual before starting the unit.

2. Drain condensate from the oil-and-air separator tank

Use the designated drain valve to remove accumulated condensate, then close the valve securely. Follow the manual’s drain procedure and never loosen fittings or remove components from a pressurized system.

3. Check the oil level

Confirm that the oil level is above the minimum mark, using the method specified for your model. If oil needs to be added, stop the compressor and follow the manual’s shutdown and depressurization instructions first.

4. Check cooling-water flow

For water-cooled compressors, make sure the cooling-water inlet and outlet valves are open and that water is flowing normally. This step does not apply to air-cooled models.

5. Check the air outlet valve

Confirm that the compressor’s air outlet valve is open as required by the system and startup procedure.

6. Check the filter bowl drains

Inspect the water-separator or filter bowls and drain collected water using their designated drain valves. Do not remove a bowl while it is under pressure.

7. Look for visible leaks

Check hoses, pipes, and connections for signs of air, oil, or water leaks. If you find a leak, correct it before operation.

Checks During Operation

1. Monitor the oil level

Check the oil level according to the procedure for your compressor. If it is low, stop the unit and follow the required depressurization steps before adding oil. Never loosen the oil-fill cap while the system is pressurized.

2. Inspect hoses and connections

Look for signs of leakage, damage, or unusual movement. Keep clear of hot surfaces and moving parts, and do not tighten connections while the compressor is running.

3. Monitor electrical readings

Check the controller or display for normal voltage and current readings. Electrical terminals should only be inspected or serviced with power isolated by a qualified person.

4. Check condensate drainage

Confirm that the water separator’s float valve or automatic drain is working and that condensate is being discharged as expected.

5. Monitor exhaust temperature

Keep the discharge temperature within the range specified in the compressor manual. The 75–95°C range in the original checklist should be treated as model-specific, not a universal range.

6. Record operating readings

Periodically record voltage, current, discharge pressure, exhaust temperature, and oil level. Keeping a log can help identify changes over time.

7. Confirm pressure-control operation

For models that use load/unload pressure control, confirm that the compressor unloads at the upper pressure limit and loads again at the lower limit. Follow the controller instructions for your model.

8. Close the enclosure doors

After completing visual checks, close the sound-insulation enclosure doors before continuing normal operation.

A Note on Safe Operation

Always use the compressor’s manual for model-specific limits and procedures. Stop the unit if you notice abnormal noise, vibration, leakage, an alarm, or readings outside the specified range. Basic operating checks such as oil level, pressure, temperature, and condensate drainage are part of routine screw-compressor maintenance.